Technická knihovna
The Megger technical library provides access to a range of additional content and resources such as technical guides, application notes and more. Use the filters to browse specific content (e.g. application notes) or refine your search to a particular electrical application area.
If you would like to see the content we have available on a particular subject or need to locate some software, simply enter a search below. Please note, you will need to create an account to access some resources.
Filtr podle aplikace:
Průvodce diagnostickým měřením izolace nad 1 kv
Spoleènost Megger vynalezla mìøení izolace pøed zaèátkem 20. století a dále vedla trh s inovacemi a technologickými zlepšeními. Proè jsme tedy vyvinuli 10kV model, když všichni ostatní výrobci konèí na 5 kV? Odpovìdí jsou normy IEEE. Spoleènost Megger vyvinula 10kV zaøízení splòující nová doporuèení pro mìøení daná IEEE. Spoleènost Megger nabízí 10kV mìøièe izolaèního odporu od roku 2001.
Zveřejněno 7 ledna 2020
Stáhnout PDF
TDM45 series
High power test and diagnostics combination for medium voltage cables.
Zveřejněno 28 listopadu 2019
Stáhnout PDF
DC test of vacuum integrity in MV switchgear
Since the 1950’s vacuum has been used as insulation media in switchgears. Even though that technology has proven to be very reliable, over time air will leak into the vacuum chamber and degrade the insulation. Also, a good practice is to measure after transport or accidents. The accepted way to test the vacuum integrity has always been through a voltage withstand test. For field tests DC test is preferred due to the weight andsize of the instruments.
Zveřejněno 19 září 2019
Stáhnout PDF
TTRU3 Phase Shifting Transformer App note
The is capable of performing turns ratio tests on any phase shifting transformer by allow-ing for phase shifts to be entered with respect to the secondary winding. But with all of the differ-ent ways phase shift is expressed, how do you know if the entered phase shift value is correct?
Zveřejněno 22 srpna 2019
Stáhnout PDF
Power swing detection/trip testing in IEDs using smart testing methodology
Power swing which is principally caused by an oscillation in active and reactive power of transmission line, consequent to an enormous disruption in power system, which if not blocked, could cause wrong operation to the distance relay which may lead to tripping the healthy part of the transmission line. In the absence of power swing function it may result in severe damage to the machines or cascading tripping in the grid resulting in blackouts. To prevent such scenarios, intelligent electronic devices (IEDs) have power swing block (PSB) detection and trip logics incorporated with distance schemes.
Zveřejněno 12 července 2019
Stáhnout PDF Přečíst celý článek